51 research outputs found

    Pump-probe differencing technique for cavity-enhanced, noise-canceling saturation laser spectroscopy

    Full text link
    We present an experimental technique enabling mechanical-noise free, cavity-enhanced frequency measurements of an atomic transition and its hyperfine structure. We employ the 532nm frequency doubled output from a Nd:YAG laser and an iodine vapour cell. The cell is placed in a traveling-wave Fabry-Perot interferometer (FPI) with counter-propagating pump and probe beams. The FPI is locked using the Pound-Drever-Hall (PDH) technique. Mechanical noise is rejected by differencing pump and probe signals. In addition, this differenced error signal gives a sensitive measure of differential non-linearity within the FPI.Comment: 3 pages, 5 figures, submitted to Optics Letter

    Laser Frequency Stabilization for LISA

    Get PDF
    This research focuses on laser ranging developments for LISA (Laser Interferometer Space Antenna), a planned NASA-ESA gravitational wave detector in space. LISA will utilize precision laser interferometry to track the changes in separation between three satellites orbiting 5 million kilometers apart. Specifically, our goal is to investigate options for laser frequency stabilization. Previous research has shown that an optical cavity system can meet LISA\u27s stability requirements, but these units are large and heavy, adding cost to the implementation. A heterodyne Mach-Zehnder interferometer could be integrated onto LISA’s existing optical bench, greatly reducing the weight, provided the interferometer meets the stability requirements. On this poster, we describe a performance comparison between an optical cavity and a Mach-Zehnder interferometer, by measuring the relative phase of stabilized lasers from the two systems. This project\u27s results will determine whether a heterodyne Mach-Zehnder is suitable for LISA

    Experimental Demonstration of Time-Delay Interferometry for the Laser Interferometer Space Antenna

    Full text link
    We report on the first demonstration of time-delay interferometry (TDI) for LISA, the Laser Interferometer Space Antenna. TDI was implemented in a laboratory experiment designed to mimic the noise couplings that will occur in LISA. TDI suppressed laser frequency noise by approximately 10^9 and clock phase noise by 6x10^4, recovering the intrinsic displacement noise floor of our laboratory test bed. This removal of laser frequency noise and clock phase noise in post-processing marks the first experimental validation of the LISA measurement scheme.Comment: 4 pages, 4 figures, to appear in Physical Review Letters end of May 201

    Picometer level displacement metrology with digitally enhanced heterodyne interferometry

    No full text
    Digitally enhanced heterodyne interferometry is a laser metrology technique employing pseudo-random codes phase modulated onto an optical carrier. We present the first characterization of the technique’s displacement sensitivity. The displacement of an optical cavity was measured using digitally enhanced heterodyne interferometry and compared to a simultaneous readout based on conventional Pound-Drever-Hall locking. The techniques agreed to within 5 pm/√Hz at 1 Hz, providing an upper bound to the displacement noise of digitally enhanced heterodyne interferometry. These measurements employed a real-time signal extraction system implemented on a field programmable gate array, suitable for closed-loop control applications. We discuss the applicability of digitally enhanced heterodyne interferometry for lock acquisition of advanced gravitational wave detectors

    High-Speed Digital Interferometry

    Get PDF
    Digitally enhanced heterodyne interferometry (DI) is a laser metrology technique employing pseudo-random noise (PRN) codes phase-modulated onto an optical carrier. Combined with heterodyne interferometry, the PRN code is used to select individual signals, returning the inherent interferometric sensitivity determined by the optical wavelength. The signal isolation arises from the autocorrelation properties of the PRN code, enabling both rejection of spurious signals (e.g., from scattered light) and multiplexing capability using a single metrology system. The minimum separation of optical components is determined by the wavelength of the PRN code

    Commissioning measurements on an Elekta Unity MR-Linac

    Get PDF
    Magnetic resonance-guided radiotherapy technology is relatively new and commissioning publications, quality assurance (QA) protocols and commercial products are limited. This work provides guidance for implementation measurements that may be performed on the Elekta Unity MR-Linac (Elekta, Stockholm, Sweden). Adaptations of vendor supplied phantoms facilitated determination of gantry angle accuracy and linac isocentre, whereas in-house developed phantoms were used for end-to-end testing and anterior coil attenuation measurements. Third-party devices were used for measuring beam quality, reference dosimetry and during treatment plan commissioning; however, due to several challenges, variations on standard techniques were required. Gantry angle accuracy was within 0.1°, confirmed with pixel intensity profiles, and MV isocentre diameter was < 0.5 mm. Anterior coil attenuation was approximately 0.6%. Beam quality as determined by TPR20,10 was 0.705 ± 0.001, in agreement with treatment planning system (TPS) calculations, and gamma comparison against the TPS for a 22.0 × 22.0 cm2 field was above 95.0% (2.0%, 2.0 mm). Machine output was 1.000 ± 0.002 Gy per 100 MU, depth 5.0 cm. During treatment plan commissioning, sub-standard results indicated issues with machine behaviour. Once rectified, gamma comparisons were above 95.0% (2.0%, 2.0 mm). Centres which may not have access to specialized equipment can use in-house developed phantoms, or adapt those supplied by the vendor, to perform commissioning work and confirm operation of the MRL within published tolerances. The plan QA techniques used in this work can highlight issues with machine behaviour when appropriate gamma criteria are set

    Progress in Interferometry for LISA at JPL

    Full text link
    Recent advances at JPL in experimentation and design for LISA interferometry include the demonstration of Time Delay Interferometry using electronically separated end stations, a new arm-locking design with improved gain and stability, and progress in flight readiness of digital and analog electronics for phase measurements.Comment: 11 pages, 9 figures, LISA 8 Symposium, Stanford University, 201

    Guidance for transport planning and policymaking in the face of an uncertain future

    Get PDF
    Uncertainty of outcome is widely recognised as a concern facing decision-makers and their advisors. In a number of spheres of policy, it appears uncertainty has intensified in the face of globalisation, economic instability, climate change, technological innovation and changing consumer preferences. How can planners and policymakers plan for an uncertain future? There is growing interest in, and use of, techniques that can help decision-making processes where deep uncertainty is involved. This paper is based upon one of the most recent international examples of a foresight exercise employed to examine uncertainty - specifically that which concerns uncertainty over the nature and extent of future demand for car travel. The principal focus of the paper is on the insights and guidance this examination of uncertainty brings forth for transport planning and policymaking. To accommodate deep uncertainty requires a flexible and open approach in terms of how policy and investment possibilities are formulated and judged. The paper argues for a focus upon the Triple Access System of spatial proximity, physical mobility and digital connectivity as a framework for policy and investment decisions that can harness flexibility and resilience. Uncertainty becomes an opportunity for decision-makers with the realisation that they are shaping the future rather than (only) responding to a predicted future. The paper outlines two forms of policymaking pathway: regime-compliant (in which adherence to trends and the nature of the world we have known pushes policy) and regime-testing (in which the nature of the world as we have known it is brought into question and vision pulls policy decisions). Stronger orientation towards regime-testing to assist in managing an uncertain future is advocated

    In-Orbit Performance of the GRACE Follow-on Laser Ranging Interferometer

    Get PDF
    The Laser Ranging Interferometer (LRI) instrument on the Gravity Recovery and Climate Experiment (GRACE) Follow-On mission has provided the first laser interferometric range measurements between remote spacecraft, separated by approximately 220 km. Autonomous controls that lock the laser frequency to a cavity reference and establish the 5 degrees of freedom two-way laser link between remote spacecraft succeeded on the first attempt. Active beam pointing based on differential wave front sensing compensates spacecraft attitude fluctuations. The LRI has operated continuously without breaks in phase tracking for more than 50 days, and has shown biased range measurements similar to the primary ranging instrument based on microwaves, but with much less noise at a level of 1 nm/Hz at Fourier frequencies above 100 mHz. © 2019 authors. Published by the American Physical Society

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead
    • …
    corecore